Elstein HLF/S

 

 

œHeat-up constant approx.. 2 min,    Cool-down is approx. 1.2min

 

œPermanent operating    temperature up    to 700 Ž

œPower densities up to 51.2 kW/m²

œIntegrated rear air space and special    material construction

œRadiator sizes and wattages can be    combined

œRadiators are optional available with @@ integrated thermocouple

œDue to the integrated heat insulation     and the relatively low weight of 230g     HLF/S radiators are suitable for     building up heating panels with high     performance.

@The special ceramic material as well    as the clectrical design guarantee for    short heat-up times and a long    operating life .

HLF/S   

  

  

   

 250

400

650

800

 

W

 

 

 

 

 

W

 

 

 

 

 

W

Max.. Power per m2 radiation area

16

25.6

41.6

51.2

 

KW

Typical operating temperature *1

420

530

660

700

 

Ž

Max. permissibe temperature

600

650

700

750

 

Ž

Wavelength range

2-10

ƒΚm

Heat-up time to 63% of final temperature

 3.5

2.6

2.2

2.0

 

min

Cool-down time to 37% of final temperature

1.7

1.4

1.2

1.2

 

min

Typical temperature of exposedgoods(guideline)

 150

200

250

280

 

Ž

*1: measured by using thermocouple@@    *To Combination Cases